Drolet Escape 1500-I Wood Insert with Faceplate

$771.64

89 in stock

Description

1. Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.

2. Optimum overall efficiency at a specific burn rate (LHV).

3. This appliance is officially tested and certified by an independent agency.

4. The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.

5. As measured per CSA B415.1-10 stack loss method.

6. Higher Heating Value of the fuel.

7. Lower Heating Value of the fuel.

8. The optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the solid fuels into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.

9. Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.

10. Carbon monoxyde.

Specifications

Fuel type

Dry cordwood (16″ recommended)

Heating area

(9)

500 – 1,800 ft²

Overall firebox volume

1.86 ft³

EPA loading volume

1.44 ft³

Maximum burn time

7 h

Maximum heat output-dry cordwood

(4)

65,000 BTU/h (19 kW)

Minimum overall heat output rate

(5)

9,800 BTU/h (2.87 kW)

Maximum overall heat output rate

52,200 BTU/h (15.3 kW)

Average overall efficiency-dry cordwood (HHV)

(6)

68 %

Average overall efficiency-dry cordwood (LHV)

(7)

73 %

Optimum efficiency

(1)

(2)

76 %

Optimum heat transfer efficiency

(8)

75 %

Average particulate emission rate

(3)

2.4 g/h

Average CO

(10)

103 g/h

Size

Medium

Premium quality blower included (CFM)

144 CFM included

Certified according to applicable standards

By an accredited laboratory (CAN/USA)

Combustion technology

Non-catalytic

Stainless-steel secondary-air system

Yes

Flue outlet diameter

6″

Distance-center of the flue outlet to back unit

5 3/4″

Distance-center of the flue outlet to side unit

12 3/4″

Recommended chimney diameter

Type of chimney

Liner – ULC-S635, CAN/ULC-S640, UL1777

Minimum chimney height

12′

Overall dimension (Width)

27 1/4″

Overall dimension (Height)

21 1/4″

Overall dimension (Depth)

22 3/8″

Door type

Single, glass with cast iron frame

Door opening size (Width)

17 1/4″

Door opening size (Height)

8 3/4″

Glass type

Ceramic glass

Glass surface – W x H

15 3/4″ x 9 3/4″

Steel thickness-body

3/16″

Steel thickness-top

5/16″

Firebox size (Width)

19 5/8″

Firebox size (Height)

11 7/8″

Firebox size (Depth)

13 1/2″

Maximum log length

18″

Log positioning

Loading over width

Firebox lined with refractory bricks

Baffle type

High quality vermiculite

Minimum fireplace opening (Width)

27 1/2″

Minimum fireplace opening (Height)

21 1/2″

Minimum fireplace opening (Depth)

High-efficiency certified appliance

Yes, EPA 2020 approved

Canadian Standard (emissions)

CSA B415.1-10

USA Standard (emissions)

EPA

Canadian Standard (safety)

ULC S628

USA Standard (safety)

UL 1482, UL 737

Warranty

Limited lifetime

Shipping weight

360 lb (163 kg)

EPA-2020

Clearances to combustibles*

Canada

USA

Clearance – Base of the unit to ceiling**

84″84″

Clearance – Combustible side mantle to unit

9″9″

Clearance – Combustible top mantle to unit

27″27″

Clearance – Combustible side wall to unit

16″16″

Clearance – Top of the unit to a 12″ combustible mantle shelf